CS300M Potentiostat/Galvanostat (Without EIS) – Single-Channel Electrochemical Workstation
CS300M Potentiostat/Galvanostat (Without EIS)
CS300M Single-Channel Potentiostat/Galvanostat for Routine Electrochemistry
The CS300M electrochemical workstation is a laboratory potentiostat/galvanostat designed for reliable DC electrochemical measurements where electrochemical impedance spectroscopy (EIS) is not required. It combines a digital waveform generator with high-speed acquisition electronics to control electrode potential or current and record the electrochemical response with strong stability—ideal for routine methods in corrosion, electroanalysis and battery cycling.
Principle of operation
In potentiostatic mode, the CS300M precisely controls the working electrode potential versus a reference electrode and measures current at the counter electrode. In galvanostatic mode, it controls current and measures the resulting potential response—supporting common 2-, 3- or 4-electrode configurations.
Key specifications and features
- Potential control range: ±10 V
- Current control range / max output: up to ±2 A (multi-range down to nA levels)
- Compliance voltage: ±21 V
- Potential resolution: down to a few µV (frequency dependent)
- Data acquisition: high-speed digitisation for transient and scan techniques
- Connectivity & software: USB control with PC software on Windows
Supported techniques (selected)
- OCP, potentiostatic I–t, galvanostatic steps
- CV, LSV, staircase voltammetry
- DPV, SWV, NPV and stripping variants
- Corrosion methods: Tafel/potentiodynamic, LPR, cyclic polarisation, EN, ZRA
- Battery DC tests: galvanostatic charge/discharge, GITT/PITT-style workflows
Typical applications
Corrosion and pitting potential screening, inhibitor/coating evaluation, electrochemical sensors, trace analysis via stripping voltammetry, and battery/supercapacitor DC cycling.
Why choose ScienceGears (AU & NZ)
ScienceGears supports CS300M users with local application guidance and system matching—pair it with compatible electrochemical cells, electrodes and accessories, or step up to EIS-capable potentiostats and current booster modules when your research requires higher power or frequency-domain analysis.
Technical Specifications
Precision engineering for accurate measurements
| Electrode configuration | 2-, 3-, or 4-electrode system |
|---|---|
| Compliance voltage | ±21 V |
| Potential control range | ±10 V (customizable to ±12 V) |
| Current control range | ±2 A (10 programmable ranges) |
| Potential resolution | 1 µV (≤10 Hz), 3 µV (>10 Hz) |
| Current resolution | 1 pA |
| EIS frequency range | EIS not supported for this model |
| Bandwidth | Covers an 8-decade frequency spectrum with both manual and automatic control options |
| Interface | USB 2.0 |
| Software | Windows 10 / 11 compatible |
| Dimensions | 36.5 × 30.5 × 16 cm |
| Weight | 6.5 kg |
Methods/Techniques
Want to learn more about these techniques?
Check out our Introduction to Electrochemical Techniques blog for an in-depth overview of their principles and applications.
Resources & Downloads
Everything you need to get started
CS300M Brochure
CS300M Brochure
Publications
Research powered by Squidstat technology
Fabrication and Shell Optimization of Synergistic TiO 2 -MoO 3 Core–Shell Nanowire Array Anode for High Energy and Power Density Lithium-Ion Batteries
High-stable nonflammable electrolyte regulated by coordination-number rule for all-climate and safer lithium-ion batteries
Solvate ionic liquid boosting favorable interfaces kinetics to achieve the excellent performance of Li4Ti5O12 anodes in Li10GeP2S12 based solid-state batteries
High Pressure Rapid Synthesis of LiCrTiO4 with Oxygen Vacancy for High Rate Lithium-Ion Battery Anodes
Abundant cilantro derived high surface area activated carbon (AC) for superior adsorption performances of cationic/anionic dyes and supercapacitor application
Arrayed Heterostructures of MoS2 Nanosheets Anchored TiN Nanowires as Efficient Pseudocapacitive Anodes for Fiber-Shaped Ammonium-Ion Asymmetric Supercapacitors
Natural Biomass-Derived Hierarchical Porous Carbon Synthesized by an in Situ Hard Template Coupled with NaOH Activation for Ultrahigh Rate Supercapacitors
High-performance all-inorganic portable electrochromic Li-ion hybrid supercapacitors toward safe and smart energy storage
A Novel Phase-Transformation Activation Process toward Ni–Mn–O Nanoprism Arrays for 2.4 V Ultrahigh-Voltage Aqueous Supercapacitors
Nitrogen-doped activated carbons derived from a co-polymer for high supercapacitor performance
Carbon-Stabilized High-Capacity Ferroferric Oxide Nanorod Array for Flexible Solid-State Alkaline Battery-Supercapacitor Hybrid Device with High Environmental Suitability
Facile Formation of a Solid Electrolyte Interface as a Smart Blocking Layer for High-Stability Sulfur Cathode
Encapsulating Sulfides into Tridymite/Carbon Reactors Enables Stable Sodium Ion Conversion/Alloying Anode with High Initial Coulombic Efficiency Over 89%
Recyclable molten-salt-assisted synthesis of N-doped porous carbon nanosheets from coal tar pitch for high performance sodium batteries
A flexible self-charged power panel for harvesting and storing solar and mechanical energy
Enhancing the efficiency of CdS quantum dot-sensitized solar cells via electrolyte engineering
Solution-Processed Laminated Perovskite Layers for High-Performance Solar Cells
Fast and Controllable Electric-Field-Assisted Reactive Deposited Stable and Annealing-Free Perovskite toward Applicable High-Performance Solar Cells
Bifunctional Dynamic Adaptive Interphase Reconfiguration for Zinc Deposition Modulation and Side Reaction Suppression in Aqueous Zinc Ion Batteries
High-Performance Aqueous Zinc Batteries Based on Organic/Organic Cathodes Integrating Multiredox Centers
A laser-scribed wearable strain sensing system powered by an integrated rechargeable thin-film zinc-air battery for a long-time continuous healthcare monitoring
Engineering Polymer Glue towards 90% Zinc Utilization for 1000 Hours to Make High-Performance Zn-Ion Batteries
Cost-effective Chlorella biomass production from dilute wastewater using a novel photosynthetic microbial fuel cell (PMFC)
Simultaneous Cr(VI) reduction and bioelectricity generation in a dual chamber microbial fuel cell
A self-driven fuel cell to recycle (NH4)2SO4 fertilizer and energy from desulfurization solution
Effect of in-situ transverse magnetic field on microstructure,mechanical properties and corrosion resistance of the directed energy deposited 316L stainless steel
Significance of waveform design to achieve bipolar electrochemical jet machining of passivating material via regulation of electrode reaction kinetics
Synthesis and characterization of highly hydrophilic self-associating terpolymers: Rheological, thermal, and corrosion protection studies
Corrosion and slurry erosion wear performances of coaxial direct laser deposited CoCrFeNiCu1-xMox high-entropy coatings by modulating the second-phase precipitation
A novel Mg-Gd-Y-Zn-Cu-Ni alloy with excellent combination of strength and dissolution via peak-aging treatment
Customer Reviews
Related Product
Explore our precision instruments designed for electrochemical research and energy applications

Admiral Instruments Squidstat Plus Potentiostat/Galvanostat (±1 A) with EIS
- Voltage Scan Range: ±10 V
- Max Current: ±1 A
- EIS Frequency Range: 10 µHz - 2 MHz
- Best Current Accuracy: 1 nA

Squidstat Solo Single-Channel Potentiostat/Galvanostat
- Voltage Scan Range: ±10 V
- Max Current: ±100 mA
- Best Current Accuracy : 1 nA
- Channels Per Unit: 1

Admiral Instruments Squidstat Penta Potentiostat/Galvanostat with FRA (EIS to 2 MHz)
- Voltage Scan Range: ±10 V
- Max Current: ±5 A
- EIS Frequency Range: 10 µHz - 2 MHz
- Best Current Accuracy: 1 nA

Squidstat Decka Potentiostat/Galvanostat with FRA (±10 A, 2 MHz EIS)
- Voltage Scan Range: ±10 V
- Max Current: ±10 A
- EIS Frequency Range: 10 µHz - 2 MHz
- Best Current Accuracy: 1 nA

Squidstat Venta High-Current Potentiostat/Galvanostat (±20 A) with 2 MHz EIS
- Voltage Scan Range: ±6 V
- Max Current: ±20 A
- EIS Frequency Range: 10 µHz - 2 MHz
- Best Current Accuracy: 1 nA

Zennium XC
- Voltage Scan Range: ±5 V and ±14 V
- Max Current: ±2 A
- EIS Frequency Range: 10 µHz to 5 MHz

CS350M
- Potential Range: ±10 V (customizable to ±12 V)
- Current Range: ±2 A (10 programmable ranges)
- EIS Frequency Range: 10 µHz to 1 MHz

CS310M Single-Channel Potentiostat/Galvanostat with EIS (Electrochemical Workstation)
- Potential range: ±10 V (customizable to ±12 V)
- Current range: ±2 A (10 programmable ranges)
- EIS frequency range: 10 µHz – 1 MHz