Squidstat Decka Potentiostat/Galvanostat with FRA (±10 A, 2 MHz EIS)
Squidstat Decka Potentiostat/Galvanostat with FRA (±10 A, 2 MHz EIS)
High-current electrochemical control with integrated EIS
The Squidstat Decka is a single-channel potentiostat/galvanostat with an integrated frequency response analyser (FRA) designed for experiments that need high current capability while maintaining precise control and analysis. In potentiostatic mode, the instrument regulates the working electrode potential vs the reference electrode using a feedback loop that drives the counter electrode. In galvanostatic mode, it controls current and records the resulting potential response. For electrochemical impedance spectroscopy (EIS), a small AC perturbation is applied and the complex impedance is measured across frequency to separate kinetics, charge transfer, and transport processes.
Key specifications and practical features
- Voltage scan range: ±10 V
- Maximum current: ±10 A (with multiple current ranges for sensitive-to-high-current work)
- EIS frequency range: 10 µHz to 2 MHz
- Operating modes: potentiostat / galvanostat with FRA capability
- Onboard data backup: 16 GB memory for failsafe recovery
- Software & automation: Squidstat User Interface (SUI) and API support on Windows, macOS, and Linux
Compatibility and typical applications
Squidstat Decka integrates naturally with 3-electrode and 5-lead electrochemical setups, including H-cells, corrosion cells, battery half-cells, and RRDE configurations (with a suitable rotator). Common applications include:
- Battery and supercapacitor testing: charge/discharge, capacity, GITT/PITT, EIS diagnostics
- Corrosion and coatings: polarisation scans, Tafel analysis, OCP monitoring, EIS
- Electrocatalysis and energy devices: high-current CV/LSV, durability studies, kinetic analysis
Why choose ScienceGears (Australia & NZ)
ScienceGears supports researchers with local guidance on configuration, pairing the Decka with the right electrochemical cells, electrodes, and accessories, and cross-linking workflows to related platforms such as potentiostats, battery cyclers, and spectroelectrochemistry/Raman-SEC cells for combined electrochemical–spectroscopic insight.
Technical Specifications
Precision engineering for accurate measurements
| Voltage Scan Range | ±10 V |
|---|---|
| Max Current | ±10 A |
| EIS Frequency Range | 10 µHz - 2 MHz |
| Best Current Accuracy | 1 nA |
| Channels Per Unit | 1 |
Methods/Techniques
Want to learn more about these techniques?
Check out our Introduction to Electrochemical Techniques blog for an in-depth overview of their principles and applications.
Resources & Downloads
Everything you need to get started
Squidstat Decka Brochure
Squidstat Decka Data Sheet
Squidstat Decka Data Sheet
Calculating Corrosion Rates From a Tafel Plot
Calculating Corrosion Rates From a Tafel Plot
Accuracy Contour Plots and EIS Accuracy
Electrochemical Impedance Spectroscopy EIS for Advanced Battery Diagnostics
Introduction to Electrochemical Impedance Spectroscopy EIS
IR Drop Compensation in Squidstats
Potentiostat Design and Engineering
Understanding and Validating Potentiostat DC Accuracy
Using Cyclic Voltammetry To Study Redox Reactions
Using Squidstats for Stack Measurements on Batteries or Fuel Cells
Using Squidstats To Perform Corrosion Testing On A Metal Coupon
Publications
Research powered by Squidstat technology
Squidstat Publications
Squidstat Publications 1
Squidstat Publications 2
Customer Reviews
Related Product
Explore our precision instruments designed for electrochemical research and energy applications

Admiral Instruments Squidstat Plus Potentiostat/Galvanostat (±1 A) with EIS
- Voltage Scan Range: ±10 V
- Max Current: ±1 A
- EIS Frequency Range: 10 µHz - 2 MHz
- Best Current Accuracy: 1 nA

Squidstat Solo Single-Channel Potentiostat/Galvanostat
- Voltage Scan Range: ±10 V
- Max Current: ±100 mA
- Best Current Accuracy : 1 nA
- Channels Per Unit: 1

Admiral Instruments Squidstat Penta Potentiostat/Galvanostat with FRA (EIS to 2 MHz)
- Voltage Scan Range: ±10 V
- Max Current: ±5 A
- EIS Frequency Range: 10 µHz - 2 MHz
- Best Current Accuracy: 1 nA

Squidstat Venta High-Current Potentiostat/Galvanostat (±20 A) with 2 MHz EIS
- Voltage Scan Range: ±6 V
- Max Current: ±20 A
- EIS Frequency Range: 10 µHz - 2 MHz
- Best Current Accuracy: 1 nA

Zennium XC
- Voltage Scan Range: ±5 V and ±14 V
- Max Current: ±2 A
- EIS Frequency Range: 10 µHz to 5 MHz

CS350M
- Potential Range: ±10 V (customizable to ±12 V)
- Current Range: ±2 A (10 programmable ranges)
- EIS Frequency Range: 10 µHz to 1 MHz

CS310M Single-Channel Potentiostat/Galvanostat with EIS (Electrochemical Workstation)
- Potential range: ±10 V (customizable to ±12 V)
- Current range: ±2 A (10 programmable ranges)
- EIS frequency range: 10 µHz – 1 MHz

CS300M Potentiostat/Galvanostat (Without EIS) – Single-Channel Electrochemical Workstation
- Potential control range: ±10 V (customizable to ±12 V)
- Current control range: ±2 A (10 programmable ranges)
- EIS frequency range: EIS not supported for this model
Still Wondering About Something?