Squidstat Decka Potentiostat/Galvanostat with FRA (±10 A, 2 MHz EIS)
Squidstat Decka Potentiostat/Galvanostat with FRA (±10 A, 2 MHz EIS)
Squidstat Decka Potentiostat/Galvanostat with FRA (±10 A, 2 MHz EIS)
Squidstat Decka Potentiostat/Galvanostat with FRA (±10 A, 2 MHz EIS)
Squidstat Decka Potentiostat/Galvanostat with FRA (±10 A, 2 MHz EIS)

Squidstat Decka Potentiostat/Galvanostat with FRA (±10 A, 2 MHz EIS)

Squidstat Decka Potentiostat/Galvanostat with FRA (±10 A, 2 MHz EIS)

High-current electrochemical control with integrated EIS

The Squidstat Decka is a single-channel potentiostat/galvanostat with an integrated frequency response analyser (FRA) designed for experiments that need high current capability while maintaining precise control and analysis. In potentiostatic mode, the instrument regulates the working electrode potential vs the reference electrode using a feedback loop that drives the counter electrode. In galvanostatic mode, it controls current and records the resulting potential response. For electrochemical impedance spectroscopy (EIS), a small AC perturbation is applied and the complex impedance is measured across frequency to separate kinetics, charge transfer, and transport processes.

Key specifications and practical features

  • Voltage scan range: ±10 V
  • Maximum current: ±10 A (with multiple current ranges for sensitive-to-high-current work)
  • EIS frequency range: 10 µHz to 2 MHz
  • Operating modes: potentiostat / galvanostat with FRA capability
  • Onboard data backup: 16 GB memory for failsafe recovery
  • Software & automation: Squidstat User Interface (SUI) and API support on Windows, macOS, and Linux

Compatibility and typical applications

Squidstat Decka integrates naturally with 3-electrode and 5-lead electrochemical setups, including H-cells, corrosion cells, battery half-cells, and RRDE configurations (with a suitable rotator). Common applications include:

  • Battery and supercapacitor testing: charge/discharge, capacity, GITT/PITT, EIS diagnostics
  • Corrosion and coatings: polarisation scans, Tafel analysis, OCP monitoring, EIS
  • Electrocatalysis and energy devices: high-current CV/LSV, durability studies, kinetic analysis

Why choose ScienceGears (Australia & NZ)

ScienceGears supports researchers with local guidance on configuration, pairing the Decka with the right electrochemical cells, electrodes, and accessories, and cross-linking workflows to related platforms such as potentiostats, battery cyclers, and spectroelectrochemistry/Raman-SEC cells for combined electrochemical–spectroscopic insight.

Technical Specifications

Precision engineering for accurate measurements

Voltage Scan Range±10 V
Max Current±10 A
EIS Frequency Range10 µHz - 2 MHz
Best Current Accuracy1 nA
Channels Per Unit1

Methods/Techniques

Open Circuit Potential MonitoringCyclic Voltammetry (CV)Staircase VoltammetryLinear Sweep Voltammetry (LSV)Linear Sweep Amperometry (LSA)Normal Pulse VoltammetryDifferential Pulse Voltammetry (DPV)Square Wave VoltammetryChronoamperometryChronopotentiometryBattery CapacityCharge / Discharge (Constant C / Constant V)Charge / Discharge (Constant R / Constant P)Constat PowerConstant ResistanceGalvanostatic Electrochemical Impedance Spectroscopy (GEIS)Potentiostatic Electrochemical Impedance Spectroscopy (PEIS)Galvanostatic Intermittent Titration Technique (GITT)Mott-Schottky (single-frequency and multi-frequency)Potentiostatic Intermittent Titration Technique (PITT)Rotating Ring Disk Electrode (RRDE)
Want to learn more about these techniques?

Check out our Introduction to Electrochemical Techniques blog for an in-depth overview of their principles and applications.

Resources & Downloads

Everything you need to get started

Squidstat Decka Brochure

Squidstat Decka Data Sheet

Squidstat Decka Data Sheet

Calculating Corrosion Rates From a Tafel Plot

Calculating Corrosion Rates From a Tafel Plot

Published: Jul 08, 2025

Accuracy Contour Plots and EIS Accuracy

Published: Jul 08, 2025

Electrochemical Impedance Spectroscopy EIS for Advanced Battery Diagnostics

Published: Jul 08, 2025

Introduction to Electrochemical Impedance Spectroscopy EIS

Published: Jul 08, 2025

IR Drop Compensation in Squidstats

Published: Jul 08, 2025

Potentiostat Design and Engineering

Published: Jul 08, 2025

Understanding and Validating Potentiostat DC Accuracy

Published: Jul 08, 2025

Using Cyclic Voltammetry To Study Redox Reactions

Published: Jul 08, 2025

Using Squidstats for Stack Measurements on Batteries or Fuel Cells

Published: Jul 08, 2025

Using Squidstats To Perform Corrosion Testing On A Metal Coupon

Published: Jul 09, 2025

Publications

Research powered by Squidstat technology

Scientific Reports
2021

Squidstat Publications

Basem S, Zakaria and Bipro Ranjan Dhar
Published : ACS Publications
Potentiostats
Scientific Reports
2022

Squidstat Publications 1

Janenipa Saupsor, Jinnawat Sangsawang, Wathanyu Kao‑ian, Falko Mahlendorf, Ahmad Azmin Mohamad, Rongrong Cheacharoen, Soorathep Kheawhom, Anongnat Somwangthanaroj
Published : ACS Publications
Nature Communications
2023

Squidstat Publications 2

Kwiyong Kim, Alexandra Zagalskaya, Jing Lian Ng, Jaeyoung Hong, Vitaly Alexandrov, Tuan Anh Pham, Xiao Su
Published : ACS Publications

Customer Reviews

reviews
5
0
4
0
3
0
2
0
1
0

Write a Review

Share your experience with this product to help others make their decision

Related Product

Explore our precision instruments designed for electrochemical research and energy applications

Admiral Instruments Squidstat Plus Potentiostat/Galvanostat (±1 A) with EIS

Admiral Instruments Squidstat Plus Potentiostat/Galvanostat (±1 A) with EIS

  • Voltage Scan Range: ±10 V
  • Max Current: ±1 A
  • EIS Frequency Range: 10 µHz - 2 MHz
  • Best Current Accuracy: 1 nA
Squidstat Solo Single-Channel Potentiostat/Galvanostat

Squidstat Solo Single-Channel Potentiostat/Galvanostat

  • Voltage Scan Range: ±10 V
  • Max Current: ±100 mA
  • Best Current Accuracy : 1 nA
  • Channels Per Unit: 1
Admiral Instruments Squidstat Penta Potentiostat/Galvanostat with FRA (EIS to 2 MHz)

Admiral Instruments Squidstat Penta Potentiostat/Galvanostat with FRA (EIS to 2 MHz)

  • Voltage Scan Range: ±10 V
  • Max Current: ±5 A
  • EIS Frequency Range: 10 µHz - 2 MHz
  • Best Current Accuracy: 1 nA
Squidstat Venta High-Current Potentiostat/Galvanostat (±20 A) with 2 MHz EIS

Squidstat Venta High-Current Potentiostat/Galvanostat (±20 A) with 2 MHz EIS

  • Voltage Scan Range: ±6 V
  • Max Current: ±20 A
  • EIS Frequency Range: 10 µHz - 2 MHz
  • Best Current Accuracy: 1 nA
Zennium XC

Zennium XC

  • Voltage Scan Range: ±5 V and ±14 V
  • Max Current: ±2 A
  • EIS Frequency Range: 10 µHz to 5 MHz
CS350M

CS350M

  • Potential Range: ±10 V (customizable to ±12 V)
  • Current Range: ±2 A (10 programmable ranges)
  • EIS Frequency Range: 10 µHz to 1 MHz
CS310M Single-Channel Potentiostat/Galvanostat with EIS (Electrochemical Workstation)

CS310M Single-Channel Potentiostat/Galvanostat with EIS (Electrochemical Workstation)

  • Potential range: ±10 V (customizable to ±12 V)
  • Current range: ±2 A (10 programmable ranges)
  • EIS frequency range: 10 µHz – 1 MHz
CS300M Potentiostat/Galvanostat (Without EIS) – Single-Channel Electrochemical Workstation

CS300M Potentiostat/Galvanostat (Without EIS) – Single-Channel Electrochemical Workstation

  • Potential control range: ±10 V (customizable to ±12 V)
  • Current control range: ±2 A (10 programmable ranges)
  • EIS frequency range: EIS not supported for this model