CIMPS – Photo-Electrochemical Light Emission Measurements

CIMPS-EMIT

CIMPS-EMIT Highlights:

CIMPS-EMIT allows integral and spectral resolved light emission measurements and can be used to characterize electroluminescent processes. For integral emission measurements, a NIST traceable calibrated photodetector is used whereas for spectral resolved measurements a UV-VIS-NIR spectrometer is used.

Like CIMPS-ABS, the emission spectrum can be measured for a different bias voltage or current, time, monitoring any other control parameter like temperature, pH, or concentration etc. The emission measurements can also be triggered manually.

CIMPS-EMIT is available in the following two configurations.

  • CIMPS-EMIT1: For integral emission measurements only, recomended in combination with CIMPS-ABS
  • CIMPS-EMIT2: For integral & spectral resolved emission measurements

Technical Specifications

Precision engineering for accurate measurements

EMIT-1

SED033 Sensor Wavelength range:350 – 1000 nm. NIST traceable calibration
Optics Cosine corrected input optics
Software CIMPS-emit Software

 

EMIT-2

SED033 Sensor Wavelength range:350 – 1000 nm. NIST traceable calibration
Optics Cosine corrected input optics
Spectrometer ILT960 Integration time: 1 ms – 60 s

Intensity Accuracy:
350 – 450 nm: ±10%
450 – 900 nm: ±5%
900 – 1050 nm: ±10%

Software CIMPS-emit Software

Resources & Downloads

Everything you need to get started

CIMPS Controlled Intensity Modulated Photo Spectroscopy

Customer Reviews

reviews
5
0
4
0
3
0
2
0
1
0

Write a Review

Share your experience with this product to help others make their decision

Related Product

Explore our precision instruments designed for electrochemical research and energy applications

CIMPS

CIMPS

  • ZENNIUM PRO potentiostat: 10 µHz – 8 MHz /±3 A /±15 V
  • Potentiostat 212: PP212 (±10 A max)
  • Monochromatic LEDs: Wavelength range: 275 nm – 1550 nm
  • Accessories: Optical bench with calibrated light feedback sensor and SIMPECC (dummy cell).
CIMPS-QE/IPCE

CIMPS-QE/IPCE

  • ZENNIUM PRO potentiostat: 10 µHz – 8 MHz /±3 A /±15 V. 5 extension slots
  • TLS Potentiostat: PP212 (±10 A max)
CIMPS-ABS

CIMPS-ABS

    CIMPS-PCS

    CIMPS-PCS

      CIMPS-FIT

      CIMPS-FIT

        CIMPS-MDTR/OIS

        CIMPS-MDTR/OIS

        • PAD4 card: Parallel acquisition of up to 4 sensors
        • Sensor: 4 sensors 1 x UV 2 x VIS 1 x IR (with filter catalogue)
        • Light source: White LED light source
        • Software: CIMPS-dtr/ois

        Still Wondering About Something?

        Explore our FAQ for fast, clear answers to the most common questions—available 24/7.