+61 493 868 335
G100-1L, G300-1L and G600-1L IP66 Peristaltic Pumps

G100-1L, G300-1L and G600-1L IP66 Peristaltic Pumps

Protected-enclosure fluid-handling drives with calibration and external automation interfaces

DESCRIPTION

The G100-1L, G300-1L and G600-1L are peristaltic pumps with IP66-rated drive enclosures for installations requiring protection from dust and water ingress within the specified enclosure rating. The family combines adjustable motor speed, flow-rate and volume-based control functions, calibration and RS485 communication. Its three drive sizes span a manufacturer-stated maximum reference single-channel flow of 750 to 3,250 mL/min, depending on the model, head and tubing combination.

Product Overview

This family offers a different enclosure and control approach from ordinary open-laboratory speed-controlled pumps. It may suit selected engineering laboratories or industrial research installations where splashes, humidity or dust affect equipment placement. The IP66 rating concerns enclosure ingress protection; it does not certify resistance to every chemical, make the pump suitable for immersion or establish compatibility with an aggressive electrolyte.

The G100-1L, G300-1L and G600-1L share the general user interface and operating modes but have different maximum motor speeds and reference flow capacities. The drive can be operated locally, linked to external signals or used with a compatible RS485 controller.

How It Works

The selected peristaltic head squeezes flexible tubing to transport liquid while keeping the normal fluid path separate from the pump mechanism. Users may select operating speed or a flow/volume-based control mode and perform calibration to account for actual delivery under the configured operating conditions. Calibration helps relate programmed settings to measured volume; it does not eliminate changes due to tubing fatigue, pressure or liquid properties.

Package / Configuration

Choose the appropriate G-series drive, a manufacturer-approved head, tubing and any required external-control cabling or mounting components. Listed compatible head families include selected BPH01, YZ, FG, BZ, DMD and DG arrangements, with model-specific reference flows. The exact head and tube must be stated in the quotation. Do not assume all listed heads fit identically or provide the same achievable flow range.

Key Features

  • IP66-rated drive housing for defined dust and water ingress protection.
  • Three model sizes with different speed and flow ceilings.
  • Continuous, timed and volume-transfer functions.
  • Flow-rate and dispensed-volume calibration support.
  • Local LCD display of speed, flow-related settings and operating information.
  • Start/stop, direction and speed inputs for external control.
  • RS485 with Modbus RTU and manufacturer-specific protocol support.
  • Parameter memory, keypad locking and fast-prime functions.

Technical Specifications

Parameter G100-1L G300-1L G600-1L
Speed range 0; 0.01–150 rpm 0; 0.01–350 rpm 0; 0.01–650 rpm
Maximum single-channel reference flow 750 mL/min 1,750 mL/min 3,250 mL/min
Speed increments 0.01 rpm below 10 rpm; 0.1 rpm from 10 to below 100 rpm; 1 rpm at higher speeds Same pattern Same pattern
Work modes Continuous / timed / volume Continuous / timed / volume Continuous / timed / volume
Calibration Flow and volume Flow and volume Flow and volume
Remote interface External signals; RS485 / Modbus RTU Same Same
Enclosure IP66 IP66 IP66
Drive dimensions 240 × 142 × 152 mm 240 × 142 × 152 mm 240 × 142 × 152 mm
Supply AC 100–240 V, 50/60 Hz Same Same
Approximate weight 3.64 kg 3.75 kg 3.75 kg


Applications

Appropriate configurations can support controlled liquid recirculation, laboratory process development, test rigs and selected chemical-industry or engineering systems. For membrane-electrode-assembly testing, the drives may be considered where the required electrolyte flow, enclosure environment and control interface are compatible. Keep chemically aggressive liquids away from the drive enclosure and assess tubing, fittings and leak containment independently.

Compatibility and Selection Guidance

Choose the smallest model that covers the required calibrated flow range with an appropriate head and tubing. Confirm whether the intended application needs continuous circulation, timed operation or a fixed delivery volume. A relatively high maximum flow rating is not a guarantee of smooth operation at a very low flow rate, and IP66 does not define the tubing's chemical resistance. For independently managed anolyte and catholyte streams, plan separate adjustable drives unless a verified independent-control arrangement is supplied.

Why Source Through ScienceGears

ScienceGears can support laboratories and engineering teams in Australia and New Zealand with G-series drive selection, flow-range interpretation, head configuration and interface requirements before quotation.

Frequently Asked Questions

What does IP66 mean for this pump?

It indicates a defined level of enclosure protection against dust and powerful water jets under the applicable rating; it does not establish chemical compatibility or permit immersion.

Does the pump measure liquid flow directly?

The pump provides calibrated flow settings. Where independent measurement or closed-loop feedback is required, verify appropriate separate instrumentation.

Can the pump deliver a set volume?

The family lists volume-transfer operating modes. Delivery performance depends on calibration and the selected fluid path.

What distinguishes the three models?

Their maximum rotational speed and manufacturer reference flow capacity increase from G100-1L to G600-1L.

Can the pump communicate with a PLC or computer?

RS485/Modbus RTU is listed, along with external-control signals; confirm electrical and protocol compatibility.

Is it automatically appropriate for corrosive electrolytes?

No. Verify all wetted materials and consider leakage, spray exposure and enclosure limitations for the actual laboratory installation.

Contact ScienceGears

Contact ScienceGears to discuss the expected flow, liquid, splash or dust exposure, automation interface and required pump-head/tubing configuration for the G-series pumps.

 

Customer Reviews

reviews
5
0
4
0
3
0
2
0
1
0

Write a Review

Share your experience with this product to help others make their decision

Related Product

Explore our precision instruments designed for electrochemical research and energy applications

Still Wondering About Something?

Explore our FAQ for fast, clear answers to the most common questions—available 24/7.

Request Quote